KH5 (6.3 MW)

KH5 (6.3 MW)

Specification

Generator Set Type KH5
 MetricImperial
Power ISO6,343 kW6.343 MW
Efficiency39.9 %39.9 %
Heat Rate 9,021 KJ/kWh8,550 BTU/kWh
Exhaust Flow 18.4 kg/s40.6 lb/s
Exhaust Gas Temp 522 C972 F
Steam Production (unfired) ~0-10 t/h~0-22,046 lbs/h
Generator Voltage Range 3-15 kV3-15 kV
Package Length 9.0 m29' 6"
Package Width 2.7 m8' 8"
Package Height 3.1 m10' 5"
Approximate Weight 39,000 kg 86,000 lbs

 

KH5 - Steam Injection
The 501-KH5 is unique in its class in the proportion of steam injection it is able to accept 0 - 100% steam injection. Power is thus increased by 60%, and efficiency increased up to 40%.

Casing steam injection is available for the KH5 sets using the Rolls-Royce 501KH engine. Centrax generator sets can be configured to follow electrical or steam demand. Steam produced by the exhaust gasses is re-injected into the engine combustion casing to raise power output by as much as 60%. Varying the amount of steam injection between zero and maximum provides unrivalled flexibility of operation.

Steam injection results in significant reductions in NOx emissions as well as substantial gains in efficiency.

Features

  • Up to 60% power increase
  • Flexibility of steam demand
  • Valuable reductions in emissions
  • Large efficiency gains (up to 40%)
  • The same 501 core engine advantages

KH5 (6.3 MW)
KH5 (6.3 MW)